System Architecture
|
|
Fibre Channel Ports
|
Switch mode (default): 24 ports 64G SFP+ ports, each supporting E_Ports, F_Ports, M_Ports, D_Ports, and EX_Ports.
8-port base configuration: additional ports are enabled with two 8-port SFP+ PODs (Ports on Demand), scaling the switch from 8 ports to 24 ports.
Brocade Access Gateway default port mapping: 16 F_Ports, 8 N_Ports
|
|
Scalability
|
Full-fabric architecture with a maximum of 239 switches
|
|
Certified Maximum
|
6000 active nodes; 56 switches, 19 hops in Brocade Fabric OS® fabrics; larger fabrics certified as required
|
|
Performance
|
Fibre Channel: 8.5Gb/s line speed, full duplex; 14.025Gb/s line speed, full duplex; 28.05Gb/s line speed, full duplex; 57.8Gb/s line speed, full duplex; auto-sensing of 8, 16, 32, and 64G port speeds.
|
|
ISL Trunking
|
Frame-based trunking with up to eight SFP+ ports per ISL trunk; up to 512Gb/s per ISL trunk. Exchange based load balancing across ISLs with Dynamic Path Selection (DPS) included in Brocade Fabric OS.
|
|
Aggregate Bandwidth
|
1.536Tb/s
|
|
Maximum Fabric Latency
|
Latency for locally switched ports is 460 ns (including FEC).
|
|
Maximum Frame Size
|
2112-byte payload
|
|
Frame Buffers
|
2000 dynamically allocated
|
|
Classes of Service
|
Class 2, Class 3, Class F (inter-switch frames)
|
|
Port Types
|
F_Port, E_Port, M_Port, D_Port (ClearLink® Diagnostic Port) on 24 SFP+ ports Brocade Access Gateway mode: F_Port and NPIV-enabled N_Port
|
|
Data Traffic Types
|
Fabric switches supporting unicast
|
|
Media Types
|
64G FC SFP+ LC connector: SWL, LWL
32G FC SFP+ LC connector: SWL, LWL, ELWL
All Brocade transceivers are PC/UPC compatible
|
|
USB
|
One USB port for system log file downloads or firmware upgrades
|
|
Fabric Services
|
BB Credit Recovery; Brocade Advanced Zoning (Default Zoning, Port/WWN Zoning, Peer Zoning); Congestion Signaling; Dynamic Path Selection (DPS); Extended Fabrics; Fabric Performance Impact Notification (FPIN); Fabric Vision; FDMI; Flow Vision; F_Port Trunking; FSPF; ISL Trunking; Management Server; Name Server; NPIV; NTP v3; Port Decommission/Fencing; QoS; Registered State Change Notification (RSCN); Slow Drain Device Quarantine (SDDQ); Target-Driven Zoning; Traffic Optimizer; Virtual Fabrics (Logical Switch, Logical Fabric); VMID+ and AppServer.
|
|
Management
|
|
Management
|
Brocade Advanced Web Tools; Brocade SANnav Management Portal and SANnav Global View; Command Line Interface (CLI); HTTP/HTTPS;RESTful API; SNMP v1/v3 (FE MIB, FC Management MIB); SSH.
|
|
Security
|
DH-CHAP (between switches and end devices); FCAP switch authentication; HTTPS; IP filtering; LDAP with IPv6; OpenLDAP; Port Binding; RADIUS; TACACS+; user-defined Role-Based Access Control (RBAC); Secure Boot; Secure Copy (SCP); Secure Syslog; SFTP; SSH v2; SSL; Switch Binding; Trusted Switch.
|
|
Management Access
|
1000Mb/s Ethernet (RJ-45) port, in-band over Fibre Channel, RJ-45 serial console port, and one USB port.
|
|
Diagnostics
|
Active Support Connectivity (ASC) and Brocade Support Link (BSL); built-in flow generator; ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; Fabric Performance Impact Monitoring (FPI);flow mirroring; Forward Error Correction (FEC); frame viewer; IO Insight for SCSI and NVMe monitoring; Monitoring and Alerting Policy Suite (MAPS); non-disruptive daemon restart; optics health monitoring; POST and embedded online/offline diagnostics,including environmental monitoring, FCping, and Pathinfo (FC traceroute); power monitoring; RAStrace logging; Rolling Reboot Detection (RRD); Syslog/Audit Log; VM Insight.
|
|
Mechanical
|
|
Enclosure
|
Back-to-front airflow (non-port-side intake); power from front, 1U
|
|
Size
|
Width: 42.88 cm (16.88 in.)
Height: 4.29 cm (1.69 in.)
Depth: 30.66 cm (12.07 in.)
|
|
System Weight
|
4.24 kg (9.35 lb) with one integrated power supply and fans, without transceivers 4.84 kg (10.67 lb) with one integrated power supply, fans, fully populated with transceivers
|
|
Environment
|
|
Operating Environment
|
Temperature: 0°C to 40°C (32°F to 104°F)
Humidity: 10% to 85% (non-condensing)
|
|
Non-operating Environment
|
Temperature: –25°C to 70°C (–13°F to 158°F)
Humidity: 10% to 90% (non-condensing)
|
|
Operating Altitude
|
Up to 3000m (9842 ft)
|
|
Storage Altitude
|
Up to 12 km (39,370 ft)
|
|
Shock
|
Operating: Up to 10G, 11 ms half-sine
Non-operating: Trapezoidal wave, 60G, 18 ms, 3G axis
|
|
Vibration
|
Operating: 1.0g sine, 0.4 grms random, 5 Hz to 500 Hz
Non-operating: 2.4g sine, 1.1 grms random, 5 Hz to 500 H
|
|
Heat Dissipation
|
Typical: 185 BTU/hr
Max: 350 BTU/hr
|
|
Power
|
|
Power Supply
|
Base switch includes a single, fixed power supply with four integrated system cooling fans.
|
|
AC Input
|
100V to 240V, maximum input current 2A
|
|
AC Input Line Frequency
|
50 Hz to 60 Hz nominal, 47 Hz to 63 Hz range
|
|
AC Power Consumption
|
Maximum power draw:
• 105W with all 24 ports operating at 64G running 100% traffic rate. (24 ports populated with 64G SWL transceivers) Fans at max speed.
• 45W for empty chassis with no optical transceivers.
Typical power draw:
• 65W with 12 ports operating at 64G running 50% traffic rate. (12 ports populated with 64G SWL transceivers) Fans at nominal speed.
• 85W with 24 ports operating at 64G running 50% traffic rate. (24 ports populated with 64G SWL transceivers) Fans at nominal speed
|