System Architecture
|
|
Fibre Channel Ports
|
128 ports (96 64G SFP+ ports, plus 16 2x64G SFP-DD ports), each supporting E_Ports, F_Ports, M_Ports, D_Ports, and EX_Ports.
48-port base configuration; additional ports are enabled with two 24-port SFP+ PODs (Ports on Demand), plus a 32-port SFP-DD POD (16 2x64G SFP-DD transceivers), scaling the switch from 48 ports to 128 ports.
|
|
Scalability
|
Full-fabric architecture with a maximum of 239 switches
|
|
Certified Maximum
|
4K active nodes; 56 switches, 19 hops in Brocade Fabric OS fabrics.
|
|
Performance
|
Fibre Channel: 8.5Gb/s line speed, full duplex; 10.53Gb/s line speed, full duplex; 14.025Gb/s line speed, full duplex; 28.05Gb/s line speed, full duplex; 57.8Gb/s line speed, full duplex; auto-sensing of 8, 10, 16, 32, and 64G port speeds. 10G optionally programmable to fixed-port speed.
|
|
ISL Trunking
|
Frame-based trunking with up to eight SFP+ ports per ISL trunk; up to 512Gb/s per ISL trunk. Exchange based load balancing across ISLs with Dynamic Path Selection (DPS) included in Brocade Fabric OS.
|
|
Aggregate Bandwidth
|
8.192Tb/s
|
|
Maximum Fabric Latency
|
Latency for locally switched ports is 460 ns (including FEC).
|
|
Maximum Frame Size
|
2112-byte payload
|
|
Frame Buffers
|
2K per switching ASIC
|
|
Classes of Service
|
Class 2, Class 3, Class F (inter-switch frames)
|
|
Port Types
|
D_Port (ClearLink® Diagnostic Port), E_Port, EX_Port, F_Port, M_Port; optional port-type control
|
|
Data Traffic Types
|
Fabric switches supporting unicast
|
|
Media Types
|
64G FC SFP+ LC connector: SWL
32G FC SFP+ LC connector: SWL, LWL, ELWL
10G FC SFP+ LC connector: SWL, LWL
2x64G FC SFP-DD SN connector: SWL
All Brocade transceivers are PC/UPC compatible.
|
|
USB
|
One standard USB port for firmware download, SupportSave, and configuration upload or download.
|
|
Fabric Services
|
BB Credit Recovery; Brocade Advanced Zoning (Default Zoning, Port/WWN Zoning, Peer Zoning); Congestion Signaling; Dynamic Path Selection (DPS); Extended Fabrics; Fabric Performance Impact Notification (FPIN); Fabric Vision; FDMI; Flow Vision; F_Port Trunking; FSPF; ISL Trunking; Management Server; Name Server; NPIV; NTP v3; Port Decommission/Fencing; QoS; Registered State Change Notification (RSCN); Slow Drain Device Quarantine (SDDQ); Target-Driven Zoning; Traffic Optimizer; Virtual Fabrics (Logical Switch, Logical Fabric); VMID+ and AppServer.
|
|
Extension
|
Integrated optional 10G Fibre Channel for DWDM MAN connectivity.
|
|
Management
|
|
Management
|
Brocade Advanced Web Tools; Brocade SANnav Management Portal and SANnav Global View; Command Line Interface (CLI); HTTP/HTTPS;RESTful API; SNMP v1/v3 (FE MIB, FC Management MIB); SSH.
|
|
Security
|
DH-CHAP (between switches and end devices); FCAP switch authentication; HTTPS; IP filtering; LDAP with IPv6; OpenLDAP; Port Binding; RADIUS; TACACS+; user-defined Role-Based Access Control (RBAC); Secure Boot; Secure Copy (SCP); Secure Syslog; SFTP; SSH v2; SSL; Switch Binding; Trusted Switch; Trusted FOS Certificates (TruFOS); root access removed.
|
|
Management Access
|
10/100/1000Mb/s Ethernet (RJ-45) port, serial console port, and USB port.
|
|
Diagnostics
|
Active Support Connectivity (ASC) and Brocade Support Link (BSL); built-in flow generator; ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; Fabric Performance Impact Monitoring (FPI);flow mirroring; Forward Error Correction (FEC); frame viewer; IO Insight for SCSI and NVMe monitoring; Monitoring and Alerting Policy Suite (MAPS); non-disruptive daemon restart; optics health monitoring; POST and embedded online/offline diagnostics,including environmental monitoring, FCping, and Pathinfo (FC traceroute); power monitoring; RAStrace logging; Rolling Reboot Detection (RRD); Syslog/Audit Log; VM Insight.
|
|
Mechanical
|
|
Enclosure
|
Front-to-back airflow; non-port-side exhaust; power from back, 2U
Back-to-front airflow; non-port-side intake; power from back,2U
|
|
Size
|
Width: 440.00 mm (17.32 in.)
Height: 86.7 mm (3.41 in.)
Depth: 609.6 mm (24.00 in.)
|
|
System Weight
|
18.92 kg (41.71 lb) with two power supplies, fans, without transceivers
21.80 kg (48.06 lb) with two power supplies, fans, fully populated with transceivers
|
|
Environment
|
|
Operating Environment
|
Temperature: 0°C to 40°C (32°F to 104°F)
Humidity: 10% to 85% (non-condensing)
|
|
Non-operating Environment
|
Temperature: –25°C to 70°C (–13°F to 158°F)
Humidity: 10% to 90% (non-condensing)
|
|
Operating Altitude
|
Up to 3000m (9842 ft)
|
|
Storage Altitude
|
Up to 12 km (39,370 ft)
|
|
Shock
|
Operating: Up to 20G, 6 ms half-sine
Non-operating: Half-sine, 33G, 11 ms, 3G axis
|
|
Vibration
|
Operating: 0.5 Grms sine, 0.4 Grms random, 5 Hz to 500 Hz
Non-operating: 2.0 Grms sine, 1.1 Grms random, 5 Hz to 500 Hz
|
|
Heat Dissipation
|
128 ports at 3195 Btu/hr
|
|
Power
|
|
Power Supply
|
Dual, hot-swappable, redundant power supplies with integral cooling fans and status LEDs. 80 Plus Gold.
|
|
AC Input
|
100 to 240 VAC nominal, 90 to 264 VAC range, maximum input current 12A @ 100V or 5A @ 240V
|
|
AC Input Line Frequency
|
50 Hz to 60 Hz nominal, 47 Hz to 63 Hz range
|
|
AC Power Consumption
|
Maximum power draw:
• 969W with all 128 ports operating at 64G (96 ports populated with 64G SWL transceivers, 16 ports populated SFP-DD SWL transceivers, each providing two ports of 64G connectivity).
• 364W for an empty chassis with no transceivers.
Typical power draw:
• 515W for Brocade G730 switch with 64 64G SW optics modules under 50% traffic rate.
• 675W for Brocade G730 switch with 128 64G SW optics modules under 50% traffic rate
|