PowerStore 500T through 9000T standard deployment models provide organizations with all the benefits of a unified storage platform for block, file and vVol data, while enabling flexible growth with the intelligent scale-up and scale-out capability of appliance clusters. In addition, automated management of resources across the cluster results in superior storage utilization and simplified administration. Designed for the modern data center, PowerStore’s data-centric design with NVMe and hardware-enabled Advanced Data Reduction and 4:1 DRR deliver critical performance and storage efficiency for both traditional and modern applications.
| Base System Enclosures | 21x2.5” drives, 2xNVRAM modules four IO modules |
| Max Drives | 96 |
| CPU per Appliance | 4 x Intel CPUs |
| NVRAM per Appliance | 2 |
| Base Enclosure | A 2U, 2 node enclosure with twenty-five 2.5” NVMe drive slots |
| Expansion Enclosure | A 2U enclosure attached to a PowerStore base enclosure with twenty-five 2.5” SAS drives slots (3 max per appliance) |
| Power Supplies | PowerStore appliances are powered by 2 redundant power supplies (PS) per enclosure. |
| Data Resiliency | Dynamic Resiliency Engine (DRE) |
| Max Mezzanine cards per Appliance | 2 |
| Max IO Modules per Appliance | 4 |
| Embedded SAS IO Ports per Appliance | 4 x 4 lane 12Gb/s SAS ports for back end connection |
| Max front end Ports per Appliance (all types) | 24 |
| Max 16/32Gb FC Ports per Appliance | 16 |
| Max 10 Gbase-T/iSCSI Ports per Appliance | 24 |
| Max 10/25 GbE/iSCSI Ports per Appliance | 24 |
| Max Raw Capacity | 898.56 TB 817.36 TiB |
| Protocols | iSCSI, NVMe-FC, FC, vVols, SMB, NFS |
| Max Initiators | 2,000 |
| Max Block Volumes/Clones | 2,000 |
| Max Volumes per Volume Group | 75 |
| Max Volume Groups | 125 |
| Max Volume Size | 256 TB |
| Max Snapshots (Block) | 50,000 |
| Max vVol Storage Containers | 50 |
| Max vVols | 19,000 |
| OS Support | See the Dell EMC Simple Support Matrix on delltechnologies.com |
| Max. Appliances | 4 |
| Max. Front End Ports | 96 |
| Max. iSCSI sessions | 2048 |
| Max Initiators | 2000 |
| Max Initiators in an Initiator Group | 1024 |
| AC Line Voltage | 8.1 A max at 200V |
| AC Line Current (operating maximum) | 1629.6 VA (1597 W) max at 200V240V (+/- 10%) |
| Power Factor | 0.95 minimum at full load, @ 200 VAC |
| Heat Dissipation (operating maximum) | 5.74 x 10 J/hr, (5,449 Btu/hr) max 200VAC |
| In-rush Current | 45 Apk “cold” per line cord, at any line voltage |
| Startup Surge Current | 120 Apk “hot” per line cord, at any line voltage |
| AC Protection | 20 A fuse on each power supply, single line |
| AC Inlet Type | IEC320-C14 or IEC320-C20 |
| Ride-through Time | 10 ms min |
| Current Sharing | ± 5 percent of full load, between power supplies |
| Weight | Empty 35.80 kg/79 lbs Full 41.7 kg/92 lbs |
| Dimensions | 8.72*44.72*79.55cm/3.43*17.61*31.32inches |