Brocade G720 Switch

Maximize performance and simplify daily tasks with a building-block Fibre Channel SAN switch

  • Description
  • Product Parameters

Overview

Realize an autonomous SAN that unleashes the performance and maximizes the ROI of your server and storage investments with the Brocade G720 Switch. The Brocade G720 Switch provides 64 ports in an ultra-dense 1U design. Delivering unmatched 64G performance and 50% lower latency compared to the previous generation, this Fibre Channel SAN switch delivers a fixed-port building block, designed to maximize performance of flash and NVMe environments to meet demanding workloads. With Brocade® Gen 7 technology, the Brocade G720 delivers far more than just speed and latency improvements. It can take the pain out of managing your data center altogether with the introduction of the autonomous SAN: a network that can self-learn, self-optimize and self-heal without intervention.
G720.png
The Brocade G720 is designed for maximum flexibility and value. This enterprise-class, Fibre Channel switch offers pay-as-you-grow scalability with Ports on Demand (PoD). Organizations can quickly, easily, and cost-effectively scale from 24 ports to 64 ports to support higher growth. The Brocade G720 provides 48 64G SFP+ ports and 8 2x64G double-density SFP-DD ports, all in an efficient 1U package. The Brocade G720 base configuration comes with 24 ports enabled and can scale to 64 ports by installing SFP licenses and a SFP-DD POD license in any order and any combination.

Highlights

• Build high-performance fabrics with a powerful, ultra-dense 64-port 1U switch with double-density optical transceivers.
•Accelerate critical workloads with 64G links.
• Maximize the performance of NVMe storage with 50% lower switching latency than Gen6.
• Enable pay-as-you-grow scalability from 24 to 64 ports—for on-demand f lexibility.
• Simplify troubleshooting by identifying and isolating issues.
• Collect comprehensive telemetry data across the fabric to enable powerful analytics.
• Visualize the data to easily understand the health and performance of the SAN.
• Automate repetitive tasks to save time and eliminate human error.
• Safeguard mission-critical workloads from vulnerabilities with Gen 7 integrated security.
System Architecture
Fibre Channel Ports
Switch mode (default): 64 ports (48 64G SFP+ ports, plus 8 2x64G SFP-DD ports), each supporting E_Ports, F_Ports, M_Ports, D_Ports, and EX_Ports.
24-port base configuration; additional ports are enabled with three 8-port SFP+ PODs (Ports on Demand),plus a 16-port SFP-DD POD (8 2x64G SFP-DD transceivers), scaling the switch from 24 ports to 64 ports.
Brocade Access Gateway default port mapping: 56 F_Ports, 8 N_Ports.
Scalability
Full-fabric architecture with a maximum of 239 switches
Certified Maximum
4K active nodes; 56 switches, 19 hops in Brocade Fabric OS fabrics.
Performance
Fibre Channel: 8.5Gb/s line speed, full duplex; 10.53Gb/s line speed, full duplex; 14.025Gb/s line speed, full duplex; 28.05Gb/s line speed, full duplex; 57.8Gb/s line speed, full duplex; auto-sensing of 8, 10, 16, 32, and 64G port speeds. 10G optionally programmable to fixed-port speed.
ISL Trunking
Frame-based trunking with up to eight SFP+ ports per ISL trunk; up to 512Gb/s per ISL trunk. Exchange based load balancing across ISLs with Dynamic Path Selection (DPS) included in Brocade Fabric OS.
Aggregate Bandwidth
4.096Tb/s
Maximum Fabric Latency
Latency for locally switched ports is 460 ns (including FEC).
Maximum Frame Size
2112-byte payload
Frame Buffers
24K per switching ASIC
Classes of Service
Class 2, Class 3, Class F (inter-switch frames)
Port Types
D_Port (ClearLink® Diagnostic Port), E_Port, EX_Port, F_Port, M_Port; optional port-type control Brocade Access Gateway mode: F_Port and NPIV-enabled N_Port.
Data Traffic Types
Fabric switches supporting unicast
Media Types
64G FC SFP+ LC connector: SWL
32G FC SFP+ LC connector: SWL, LWL, ELWL
10G FC SFP+ LC connector: SWL, LWL
2x64G FC SFP-DD SN connector: SWL
All Brocade transceivers are PC/UPC compatible.
USB
One standard USB port for firmware download, SupportSave, and configuration upload or download.
Fabric Services
BB Credit Recovery; Brocade Advanced Zoning (Default Zoning, Port/WWN Zoning, Peer Zoning); Congestion Signaling; Dynamic Path Selection (DPS); Extended Fabrics; Fabric Performance Impact Notification (FPIN); Fabric Vision; FDMI; Flow Vision; F_Port Trunking; FSPF; ISL Trunking; Management Server; Name Server; NPIV; NTP v3; Port Decommission/Fencing; QoS; Registered State
Change Notification (RSCN); Slow Drain Device Quarantine (SDDQ); Target-Driven Zoning; Traffic Optimizer; Virtual Fabrics (Logical Switch, Logical Fabric); VMID+ and AppServer.
Extension
Fibre Channel, in-flight compression (Brocade LZO) and encryption (AES-GCM-256 encryption on FC ISLs [E_Port]); integrated optional 10G Fibre Channel for DWDM MAN connectivity
Management
Management
Brocade Advanced Web Tools; Brocade SANnav Management Portal and SANnav Global View; Command Line Interface (CLI); HTTP/HTTPS;RESTful API; SNMP v1/v3 (FE MIB, FC Management MIB); SSH.
Security
DH-CHAP (between switches and end devices); FCAP switch authentication; HTTPS; IP filtering; LDAP with IPv6; OpenLDAP; Port Binding; RADIUS; TACACS+; user-defined Role-Based Access Control (RBAC); Secure Boot; Secure Copy (SCP); Secure Syslog; SFTP; SSH v2; SSL; Switch Binding; Trusted Switch.
Management Access
10/100/1000Mb/s Ethernet (RJ-45) port and serial console port (mini-USB)
Diagnostics
Active Support Connectivity (ASC) and Brocade Support Link (BSL); built-in flow generator; ClearLink optics and cable diagnostics, including electrical/optical loopback, link traffic/latency/distance; Fabric Performance Impact Monitoring (FPI);flow mirroring; Forward Error Correction (FEC); frame viewer; IO Insight for SCSI and NVMe monitoring; Monitoring and Alerting Policy Suite (MAPS); non-disruptive daemon restart; optics health monitoring; POST and embedded online/offline diagnostics,including environmental monitoring, FCping, and Pathinfo (FC traceroute); power monitoring; RAStrace logging; Rolling Reboot
Detection (RRD); Syslog/Audit Log; VM Insight.
Mechanical
Enclosure
Front-to-back airflow; non-port-side exhaust; power from back, 1U
Back-to-front airflow; non-port-side intake; power from back,1U
Size
Width: 440.00 mm (17.32 in.)
Height: 43.90 mm (1.73 in.)
Depth: 355.60 mm (14.00 in.)
System Weight
7.34 kg (16.18 lb) with two power supplies, fans, without transceivers
8.78 kg (19.36 lb) with two power supplies, fans, fully populated with transceivers
Environment
Operating Environment
Temperature: 0°C to 40°C (32°F to 104°F)
Humidity: 8% to 90% (non-condensing)
Non-operating Environment
Temperature: –25°C to 70°C (–13°F to 158°F)
Humidity: 8% to 90% (non-condensing)
Operating Altitude
Up to 3000m (9842 ft)
Storage Altitude
Up to 12 km (39,370 ft)
Shock
Operating: Up to 20G, 6 ms half-sine
Non-operating: Half-sine, 33G, 11 ms, 3G axis
Vibration
Operating: 0.25 Grms sine, 0.40 Grms random, 5 Hz to 500 Hz
Nonoperating: 5 Hz at 0.50 Grms; 10–500 Hz at 1.00 Grms (sine vibration); 3–500 Hz at 1.12 Grms (random vibration)
Heat Dissipation
64 ports at 1192 Btu/hr
Power
Power Supply
Dual, hot-swappable redundant power supplies with integrated system cooling fans. 80 Plus Gold.
AC Input
90V to 264V, maximum input current 4.5A
AC Input Line Frequency
50 Hz to 60 Hz nominal, 47 Hz to 63 Hz range
AC Power Consumption
Maximum power draw:
• 349W with all 64 ports operating at 64G (48 ports populated with 64G SWL transceivers and 8 ports populated with 2x64G SFP-DD SWL transceivers).
• 57W for an empty chassis with no transceivers.
Typical power draw:
• 155W for Brocade G720 switch with 32 64G SW optics modules under 50% traffic rate.
• 252W for Brocade G720 switch with 64 64G SW optics modules under 50% traffic rate

Get a Free Quote